Patient: | PED ECHO SHORT REPORT (#45531420070530) |
Manufacturer: | Philips Medical Systems |
Completion Flag: | PARTIAL |
Verification Flag: | UNVERIFIED |
Content Date/Time: | 2007-05-30 14:55:15 |
Patient's Name:
PED ECHO SHORT REPORT
Patient ID:
45531420070530
Exam date:
2007-05-30
Study date:
2007-05-30
Concept Modifier: Finding Site = Aortic root (F-04403, SRT)
Diameter:
16 mm
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Diameter:
16 mm
Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Cardiovascular Orifice Area:
200.999999999999 mm2
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Concept Modifier: Finding Site = Interventricular septum (T-32410, SRT)
Thickness:
9.86 mm
Inferred from: Spatial Coordinates [Annex 1]
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Thickness:
9.86 mm
Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Concept Modifier: Finding Site = Left Ventricle (T-32600, SRT)
Internal Dimension:
31.2 mm
Inferred from: Spatial Coordinates [Annex 2]
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Internal Dimension:
31.2 mm
Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Internal Dimension:
19.7 mm
Inferred from: Spatial Coordinates [Annex 3]
Concept Modifier: Cardiac Cycle Point = End Systole (109070, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Internal Dimension:
19.7 mm
Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Cardiac Cycle Point = End Systole (109070, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Thickness:
11.7 mm
Inferred from: Spatial Coordinates [Annex 4]
Concept Modifier: Finding Site = Left Ventricle Posterior Wall (C12243-01, 99PMSBLUS)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Thickness:
11.7 mm
Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Finding Site = Left Ventricle Posterior Wall (C12243-01, 99PMSBLUS)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Volume:
30400 mm3
Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Volume:
38500 mm3
Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Volume:
7650 mm3
Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Cardiac Cycle Point = End Systole (109070, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Volume:
12200 mm3
Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Cardiac Cycle Point = End Systole (109070, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Ejection Fraction:
74.8 %
Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Ejection Fraction:
68.3 %
Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Fractional Shortening:
36.9 %
Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Fractional Shortening:
36.9 %
Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Interventricular Septum to Posterior Wall Thickness Ratio:
0.843 1
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Stroke Volume:
22800 mm3
Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Stroke Volume:
26300 mm3
Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)
Selected from: Image = US image
Selected from: Image = US image
Selected from: Image = US image
Selected from: Image = US image