Patient: PED ECHO SHORT REPORT (#45531420070530)
Manufacturer: Philips Medical Systems
Completion Flag: PARTIAL
Verification Flag: UNVERIFIED
Content Date/Time: 2007-05-30 14:55:15

Pediatric Echocardiography Procedure Report

Patient Characteristics

Patient's Name:
PED ECHO SHORT REPORT

Patient ID:
45531420070530

Exam date:
2007-05-30

Study date:
2007-05-30

Findings

Concept Modifier: Finding Site = Aortic root (F-04403, SRT)

Measurement Group

Diameter:
16 mm

Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Diameter:
16 mm

Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Cardiovascular Orifice Area:
200.999999999999 mm2

Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Findings

Concept Modifier: Finding Site = Interventricular septum (T-32410, SRT)

Measurement Group

Thickness:
9.86 mm

Inferred from: Spatial Coordinates [Annex 1]
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Thickness:
9.86 mm

Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Findings

Concept Modifier: Finding Site = Left Ventricle (T-32600, SRT)

Measurement Group

Internal Dimension:
31.2 mm

Inferred from: Spatial Coordinates [Annex 2]
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Internal Dimension:
31.2 mm

Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Internal Dimension:
19.7 mm

Inferred from: Spatial Coordinates [Annex 3]
Concept Modifier: Cardiac Cycle Point = End Systole (109070, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Internal Dimension:
19.7 mm

Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Cardiac Cycle Point = End Systole (109070, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Thickness:
11.7 mm

Inferred from: Spatial Coordinates [Annex 4]
Concept Modifier: Finding Site = Left Ventricle Posterior Wall (C12243-01, 99PMSBLUS)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Thickness:
11.7 mm

Concept Modifier: Derivation = Mean (R-00317, SRT)
Properties: Selection Status = Mean value chosen (121412, DCM)
Concept Modifier: Finding Site = Left Ventricle Posterior Wall (C12243-01, 99PMSBLUS)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Volume:
30400 mm3

Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Volume:
38500 mm3

Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Cardiac Cycle Point = End Diastole (F-32011, SRT)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Volume:
7650 mm3

Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Cardiac Cycle Point = End Systole (109070, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Volume:
12200 mm3

Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Cardiac Cycle Point = End Systole (109070, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Ejection Fraction:
74.8 %

Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Ejection Fraction:
68.3 %

Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Fractional Shortening:
36.9 %

Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Fractional Shortening:
36.9 %

Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Interventricular Septum to Posterior Wall Thickness Ratio:
0.843 1

Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Stroke Volume:
22800 mm3

Concept Modifier: Measurement Method = Cube Method (125206, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Stroke Volume:
26300 mm3

Concept Modifier: Measurement Method = Teichholz (125209, DCM)
Concept Modifier: Image Mode = 2D mode (G-03A2, SRT)

Annex

Annex 1

Spatial Coordinates:
Polyline

Selected from: Image = US image

Annex 2

Spatial Coordinates:
Polyline

Selected from: Image = US image

Annex 3

Spatial Coordinates:
Polyline

Selected from: Image = US image

Annex 4

Spatial Coordinates:
Polyline

Selected from: Image = US image


This page was generated from a DICOM Structured Reporting document by OFFIS DCMTK 3.5.3.